<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Blog Sparks Direct &#187; rafiki twinflex</title>
	<atom:link href="http://blog.sparksdirect.co.uk/tag/rafiki-twinflex/feed/" rel="self" type="application/rss+xml" />
	<link>http://blog.sparksdirect.co.uk</link>
	<description>Reviews of the lights, dimmers, switches and sockets, electrical items, heating and ventilation, fire and security items on our site</description>
	<lastBuildDate>Tue, 16 Mar 2010 12:37:03 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.2</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>The Rafiki Multipoint Detector, central to all Rafiki fire alarm systems</title>
		<link>http://blog.sparksdirect.co.uk/the-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems/</link>
		<comments>http://blog.sparksdirect.co.uk/the-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems/#comments</comments>
		<pubDate>Wed, 17 Jun 2009 08:49:58 +0000</pubDate>
		<dc:creator>sparksdirect</dc:creator>
				<category><![CDATA[fire alarms]]></category>
		<category><![CDATA[new technologies]]></category>
		<category><![CDATA[technical data]]></category>
		<category><![CDATA[website update]]></category>
		<category><![CDATA[addressable systems]]></category>
		<category><![CDATA[intelligent conventional detector]]></category>
		<category><![CDATA[multipoint detector]]></category>
		<category><![CDATA[multipoint modes of detection]]></category>
		<category><![CDATA[Rafiki control panel]]></category>
		<category><![CDATA[rafiki multipoint]]></category>
		<category><![CDATA[rafiki twinflex]]></category>
		<category><![CDATA[Twinflex plus]]></category>

		<guid isPermaLink="false">http://blog.sparksdirect.co.uk/?p=1373</guid>
		<description><![CDATA[The Rafiki Multipoint Detector is a multi-criteria detector, micro-processor control and integral sounder.
The ‘Multipoint’ detector has set new standards in detector technology, using microprocessor control even as a conventional detector and offering the installer a full range of detection capabilities with audible warning in one compact device. Specifiers and installers who choose the Multipoint detector, [...]]]></description>
			<content:encoded><![CDATA[<blockquote><p>The Rafiki Multipoint Detector is a multi-criteria detector, micro-processor control and integral sounder.</p></blockquote>
<p><a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html"><img class="alignleft" title="Rafiki Twinflex Multipoint Combined Detector and Sounder" src="http://blog.sparksdirect.co.uk/images/multipoint-sounder.jpg" alt="" width="350" height="267" /></a>The <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=multipoint+detector&amp;search_in_description=1" target="_blank"><strong>‘Multipoint’ detector</strong></a> has set new standards in detector technology, using <span style="text-decoration: underline;">microprocessor control</span> even as <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a" target="_blank">a conventional detector</a> and offering the installer a full range of detection capabilities with audible warning in one compact device. Specifiers and installers who choose the <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=multipoint+detector&amp;search_in_description=1" target="_blank">Multipoint detector</a>, do so secure in the knowledge that <em>the fire detection performance of the detector can be matched to the environment in which it is installed</em> – and changed any time during the lifetime of the installation. The mode of detection required can be simply changed by <em>configuring the DIL switch</em> in the detector electronics module, or v<a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank"><em>ia the control panel/ PC on addressable detectors</em></a>. All modes are compliant with European detector type specifications, and are suitable for use in installations compliant with <a href="http://blog.sparksdirect.co.uk/fire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki/">BS5839: Part 1: 2002, Part 6 2004</a> when used in conjunction with <strong><a href="http://www.sparksdirect.co.uk/2-zone-twinflex-plus-fire-alarm-contractor-kit-from-rafiki-p-15340.html" target="_blank">the ‘Twinflex Plus’ system.</a></strong></p>
<p>The <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-detector-with-no-sounder-p-15332.html" target="_blank"><strong>Twinflex Intelligent conventional detector</strong></a> can be set to any one of the above modes as well as a <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank"><strong>Combined Mode</strong></a> (Smoke 2 &amp; Heat 2) where a smoke or heat source can trigger a fire decision. This means that the end user is given optimum fire protection, even if the installer is unsure of the use of the particular area where the detector is sited. As part of <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank">the Twinflex system</a> all <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=twinflex&amp;search_in_description=1" target="_blank">Twinflex products</a> including <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">the Twinflex Multipoint detector</a> feature an <span style="text-decoration: underline;">End of Line monitoring switch</span>, which <em>negates the need for End of Line resistors</em>.</p>
<ul>
<li><a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank"><strong>The Rafiki Multipoint Detector</strong></a> also has the unique benefit of an optional full specification integral sounder. A 90dBA output can be achieved. The <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=twinflex&amp;search_in_description=1" target="_blank">Twinflex Intelligent conventional detector</a> can be set to 3 different sound patterns, as well as switched off, with 2 sound output levels.</li>
<li>To ensure the detection capabilities of <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">the Multipoint</a> are never compromised it self-calibrates every 6 hours. It continuously monitors for dust contamination, until, over a period of time depending on the environment it reaches a point where the chamber becomes saturated. Before this can develop into a false alarm situation, <a href="http://www.sparksdirect.co.uk/2-zone-twinflex-plus-fire-alarm-control-panel-p-15337.html" target="_blank">the panel</a> will indicate that <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">a Multipoint</a> needs attention.</li>
<li>To make maintenance easy, <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">the Multipoint</a> features a disposable optical chamber. This means the chamber can be simply thrown away, and replaced economically when necessary.</li>
</ul>
<h4>Multipoint Modes of Detection</h4>
<ul>
<li><strong>Smoke 1</strong><br />
Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires (chemical stores etc), or fires that need to be detected extremely quickly.</li>
<li><strong>Smoke 2</strong><br />
Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.</li>
<li><strong>Smoke 3</strong><br />
This setting is designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period, before a fire decision is made. This setting, for example, is ideal for hotel bedrooms with en-suite shower rooms, the end user can change the setting from smoke 2 to smoke 3 if nuisance alarms are becoming a problem – whilst still offering optimum protection of a smoke detection setting, especially if this is what has been specified.</li>
<li><strong>Heat 1 (Rate of Rise)<br />
</strong>Used where a standard rate of rise detector would normally be used.</li>
<li><strong>Heat 2 </strong>(Standard Fixed Temperature &#8211; 58ºC approx)<br />
Used where a standard fixed temperature heat detector would normally be fitted, suitable for kitchens, etc.</li>
<li><strong>Heat 3 </strong>(High Fixed Temperature &#8211; 90ºC approx)<br />
Used where a high fixed temperature heat detector would normally be fitted, suitable for boiler rooms, etc.</li>
</ul>
<p><a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-detector-with-no-sounder-p-15332.html"><img class="alignleft" title="Rafiki Twinflex Multipoint Detector with No Sounder" src="http://blog.sparksdirect.co.uk/images/multipoint-no-sounder.jpg" alt="" width="350" height="264" /></a>View <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank"><strong>the Rafiki Conventional and Analogue Fire Alarm Systems</strong></a> &#8211; under <a href="http://www.sparksdirect.co.uk/fire-and-security-fire-alarms-c-74_138.html" target="_blank">the Fire alarms</a> section, <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html" target="_blank">Conventional and Analogue systems</a> &#8211; including the <a title="Rafiki Twinflex Hatari Sounder, White sounder" href="http://www.sparksdirect.co.uk/rafiki-twinflex-hatari-sounder-white-sounder-p-15334.html" target="_blank">Rafiki Twinflex Hatari Sounder</a>, <a title="Rafiki Twinflex Multipoint Combined Detector and Sounder" href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">the Rafiki Twinflex Multipoint Combined Detector and Sounder</a>, <a title="Rafiki Twinflex Manual Call Point with Sounder" href="http://www.sparksdirect.co.uk/rafiki-twinflex-manual-call-point-with-sounder-p-15336.html" target="_blank">the Rafiki Twinflex Manual Call Point with Sounder</a>,<a title="2 Zone Twinflex PLUS Fire Alarm Control Panel" href="http://www.sparksdirect.co.uk/2-zone-twinflex-plus-fire-alarm-control-panel-p-15337.html" target="_blank"> the 2 Zone Twinflex PLUS Fire Alarm Control Panel</a>, or <a title="8 Zone Twinflex PLUS Fire Alarm Control Panel Rafiki" href="http://www.sparksdirect.co.uk/8-zone-twinflex-plus-fire-alarm-control-panel-rafiki-p-15339.html" target="_blank">the 8 Zone Twinflex PLUS Fire Alarm Control Panel Rafiki</a>. <strong></strong></p>
<p>Read more about the<a href="../user-responsibilities-in-the-testing-and-maintanance-of-the-fire-alarm-system/"> generally accepted guidelines</a> by <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank"><strong>Rafiki</strong></a>, <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=aico&amp;search_in_description=1" target="_blank"><strong>Aico</strong></a>, and other <a href="http://www.sparksdirect.co.uk/fire-and-security-fire-alarms-c-74_138.html" target="_blank"><strong>Fire Alarms</strong></a> manufacturers, (they are also commonly accepted for all the domestic, commercial and industrial properties in UK); the <span style="text-decoration: underline;">Rafiki advices for Fire Alarms</span>, some of the guidelines provided by <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank"><strong>Rafiki</strong></a>(intelligent fire technology) – check out <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank">the Rafiki series of industrial/commercial fire alarm systems</a> (like the <a href="../introducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint/">Rafiki Twinflex</a>), found at <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html" target="_blank">The Conventional</a> <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a" target="_blank">and Analogue</a> <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank">Fire Alarms</a>. For more details about <a href="http://www.fire-detect.co.uk/" target="_blank">the fire alarms</a>, visit the <a href="http://www.fire-detect.co.uk/" target="_blank"><strong>Fire-Detect</strong> website</a>(see a list of articles about the fire alarms <a href="http://www.sparksdirect.co.uk/page_4.html" target="_blank">here</a> and <a href="http://www.fire-detect.co.uk/questions-and-answers-aico-fire-detectors.html" target="_blank">here</a>).</p>
<p>N.B. These details are as presented by <a href="http://www.rafikiprotection.com/" target="_blank"><strong>Rafiki</strong></a> on their website(<a href="http://www.rafikiprotection.com/multipoint.aspx" target="_blank">Multipoint Specs</a>).</p>

<div class="sociable">
<div class="sociable_tagline">
<strong>Share this article:</strong>
</div>
<ul>
	<li class="sociablefirst"><a rel="nofollow"  target="_blank" href="http://www.printfriendly.com/print?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;partner=sociable" title="Print"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/printfriendly.png" title="Print" alt="Print" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://digg.com/submit?phase=2&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;title=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems&amp;bodytext=The%20Rafiki%20Multipoint%20Detector%20is%20a%20multi-criteria%20detector%2C%20micro-processor%20control%20and%20integral%20sounder.%0D%0AThe%20%E2%80%98Multipoint%E2%80%99%20detector%20has%20set%20new%20standards%20in%20detector%20technology%2C%20using%20microprocessor%20control%20even%20as%20a%20conventional%20detector%20and%20o" title="Digg"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/digg.png" title="Digg" alt="Digg" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://sphinn.com/index.php?c=post&amp;m=submit&amp;link=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F" title="Sphinn"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/sphinn.png" title="Sphinn" alt="Sphinn" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://delicious.com/post?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;title=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems&amp;notes=The%20Rafiki%20Multipoint%20Detector%20is%20a%20multi-criteria%20detector%2C%20micro-processor%20control%20and%20integral%20sounder.%0D%0AThe%20%E2%80%98Multipoint%E2%80%99%20detector%20has%20set%20new%20standards%20in%20detector%20technology%2C%20using%20microprocessor%20control%20even%20as%20a%20conventional%20detector%20and%20o" title="del.icio.us"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/delicious.png" title="del.icio.us" alt="del.icio.us" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.facebook.com/share.php?u=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;t=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems" title="Facebook"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/facebook.png" title="Facebook" alt="Facebook" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.google.com/bookmarks/mark?op=edit&amp;bkmk=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;title=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems&amp;annotation=The%20Rafiki%20Multipoint%20Detector%20is%20a%20multi-criteria%20detector%2C%20micro-processor%20control%20and%20integral%20sounder.%0D%0AThe%20%E2%80%98Multipoint%E2%80%99%20detector%20has%20set%20new%20standards%20in%20detector%20technology%2C%20using%20microprocessor%20control%20even%20as%20a%20conventional%20detector%20and%20o" title="Google Bookmarks"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/googlebookmark.png" title="Google Bookmarks" alt="Google Bookmarks" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="mailto:?subject=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems&amp;body=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F" title="email"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/email_link.png" title="email" alt="email" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.friendfeed.com/share?title=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems&amp;link=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F" title="FriendFeed"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/friendfeed.png" title="FriendFeed" alt="FriendFeed" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://hellotxt.com/?status=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems+http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F" title="HelloTxt"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/hellotxt.png" title="HelloTxt" alt="HelloTxt" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.linkedin.com/shareArticle?mini=true&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;title=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems&amp;source=Blog+Sparks+Direct+Reviews+of+the+lights%2C+dimmers%2C+switches+and+sockets%2C+electrical+items%2C+heating+and+ventilation%2C+fire+and+security+items+on+our+site&amp;summary=The%20Rafiki%20Multipoint%20Detector%20is%20a%20multi-criteria%20detector%2C%20micro-processor%20control%20and%20integral%20sounder.%0D%0AThe%20%E2%80%98Multipoint%E2%80%99%20detector%20has%20set%20new%20standards%20in%20detector%20technology%2C%20using%20microprocessor%20control%20even%20as%20a%20conventional%20detector%20and%20o" title="LinkedIn"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/linkedin.png" title="LinkedIn" alt="LinkedIn" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="https://favorites.live.com/quickadd.aspx?marklet=1&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;title=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems" title="Live"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/live.png" title="Live" alt="Live" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.printfriendly.com/print?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;partner=sociable" title="PDF"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/pdf.png" title="PDF" alt="PDF" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://posterous.com/share?linkto=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;title=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems&amp;selection=The%20Rafiki%20Multipoint%20Detector%20is%20a%20multi-criteria%20detector%2C%20micro-processor%20control%20and%20integral%20sounder.%0D%0AThe%20%E2%80%98Multipoint%E2%80%99%20detector%20has%20set%20new%20standards%20in%20detector%20technology%2C%20using%20microprocessor%20control%20even%20as%20a%20conventional%20detector%20and%20o" title="Posterous"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/posterous.png" title="Posterous" alt="Posterous" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://reddit.com/submit?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;title=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems" title="Reddit"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/reddit.png" title="Reddit" alt="Reddit" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.stumbleupon.com/submit?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;title=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems" title="StumbleUpon"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/stumbleupon.png" title="StumbleUpon" alt="StumbleUpon" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://buzz.yahoo.com/submit/?submitUrl=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F&amp;submitHeadline=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems&amp;submitSummary=The%20Rafiki%20Multipoint%20Detector%20is%20a%20multi-criteria%20detector%2C%20micro-processor%20control%20and%20integral%20sounder.%0D%0AThe%20%E2%80%98Multipoint%E2%80%99%20detector%20has%20set%20new%20standards%20in%20detector%20technology%2C%20using%20microprocessor%20control%20even%20as%20a%20conventional%20detector%20and%20o&amp;submitCategory=science&amp;submitAssetType=text" title="Yahoo! Buzz"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/yahoobuzz.png" title="Yahoo! Buzz" alt="Yahoo! Buzz" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://technorati.com/faves?add=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F" title="Technorati"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/technorati.png" title="Technorati" alt="Technorati" class="sociable-hovers" /></a></li>
	<li class="sociablelast"><a rel="nofollow"  target="_blank" href="http://twitter.com/home?status=The%20Rafiki%20Multipoint%20Detector%2C%20central%20to%20all%20Rafiki%20fire%20alarm%20systems%20-%20http%3A%2F%2Fblog.sparksdirect.co.uk%2Fthe-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems%2F" title="Twitter"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/twitter.png" title="Twitter" alt="Twitter" class="sociable-hovers" /></a></li>
</ul>
</div>
]]></content:encoded>
			<wfw:commentRss>http://blog.sparksdirect.co.uk/the-rafiki-multipoint-detector-central-to-all-rafiki-fire-alarm-systems/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Checkpoint alarm confirmation and HMO’s: Eliminate the problem of false alarms</title>
		<link>http://blog.sparksdirect.co.uk/checkpoint-alarm-confirmation-and-hmo%e2%80%99s-eliminate-the-problem-of-false-alarms/</link>
		<comments>http://blog.sparksdirect.co.uk/checkpoint-alarm-confirmation-and-hmo%e2%80%99s-eliminate-the-problem-of-false-alarms/#comments</comments>
		<pubDate>Sat, 13 Jun 2009 10:51:32 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[ask Mr Sparks]]></category>
		<category><![CDATA[fire alarms]]></category>
		<category><![CDATA[standards and regulations]]></category>
		<category><![CDATA[technical data]]></category>
		<category><![CDATA[website update]]></category>
		<category><![CDATA[bs5839]]></category>
		<category><![CDATA[checkpoint alarm]]></category>
		<category><![CDATA[false alarms]]></category>
		<category><![CDATA[fire detectors]]></category>
		<category><![CDATA[integral sounder]]></category>
		<category><![CDATA[multipoint detector]]></category>
		<category><![CDATA[Rafiki]]></category>
		<category><![CDATA[Rafiki checkpoint]]></category>
		<category><![CDATA[Rafiki control panel]]></category>
		<category><![CDATA[rafiki multipoint]]></category>
		<category><![CDATA[rafiki twinflex]]></category>
		<category><![CDATA[Twinflex plus]]></category>

		<guid isPermaLink="false">http://blog.sparksdirect.co.uk/?p=1333</guid>
		<description><![CDATA[With the Rafiki Twinflex Solutions, you have a ‘Checkpoint’ alarm confirmation and HMO’s and you eliminate the problem of false alarms in: Hostels, Nursing Homes, Flats, Hotels, Bedsits, B&#38;B&#8217;s, etc.
  The Rafiki Twinflex plus is a patented, 2 wire intelligent fire alarm system suitable for the majority of fire alarm installations. The Twinflex plus [...]]]></description>
			<content:encoded><![CDATA[<p>With<a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=twinflex+plus&amp;search_in_description=1" target="_blank"><strong> the Rafiki Twinflex Solutions</strong></a>, you have a ‘Checkpoint’ alarm confirmation and HMO’s and you eliminate the problem of false alarms in: <em>Hostels, Nursing Homes, Flats, Hotels, Bedsits, B&amp;B&#8217;s</em>, etc.</p>
<p><a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki+twinflex&amp;search_in_description=1" target="_blank"><strong> </strong><strong> </strong></a><strong><a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html"><img class="alignleft" title="Twinflex plus is a patented, 2 wire intelligent fire alarm system" src="http://blog.sparksdirect.co.uk/images/twinflex-checkpoint.jpg" alt="" width="191" height="140" /></a></strong>The Rafiki Twinflex plus is a patented, 2 wire intelligent <a href="http://www.sparksdirect.co.uk/fire-and-security-fire-alarms-c-74_138.html" target="_blank">fire alarm system</a> suitable for the majority of fire alarm installations. <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html" target="_blank">The Twinflex plus</a> also has the option of the added feature of  <span style="text-decoration: underline;">&#8216;checkpoint&#8217; alarm confirmation</span>.</p>
<p><a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=checkpoint+alarm&amp;search_in_description=1" target="_blank"><strong>Checkpoint alarm confirmation</strong></a> drastically reduces the disruption and cost associated with false alarms, particularly during the settling-in-period following installation. Introduction of mandatory licensing of HMO’s of three stories or more was introduced in April 2006.</p>
<p>Licensing of HMO’s is mandatory for all local authorities and all buildings that are registered must comply, amongst other things, with fire regulations contained within <a href="Alexa Traffic Rank for http://www.theiet.org/publishing/wiring-regulations/mag/2005/17-firealarms.cfm?type=pdf: 64,259www.theiet.org/publishing/wiring-regulations/mag/2005/17-firealarms.cfm?type=pdf " target="_blank">BS5839 part 6</a>, the main code of practice for installations within HMO’s and in some cases <a href="http://www.bsigroup.com/Shop/Publication-Detail/?pid=000000000030171701" target="_blank">BS5839 Part 1</a> may also be applicable in communal areas.<a href="http://www.sparksdirect.co.uk/fire-and-security-fire-alarms-c-74_138.html" target="_blank"></a></p>
<p><a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html"><img class="alignleft" title="Eliminate the problem of false alarms with Rafiki Twinflex Checkpoint" src="http://blog.sparksdirect.co.uk/images/twinflex-flowchart.jpg" alt="" width="350" height="636" /></a><a href="http://www.sparksdirect.co.uk/fire-and-security-fire-alarms-c-74_138.html" target="_blank">False alarms</a> are a huge problem in within these types of buildings and installers are constantly looking for an early warning fire alarm system without the disruption of false alarms.</p>
<p>There are <em>over 485,000 false alarms</em> attended by the Fire Services each year and hundreds of thousands more that are not recorded, sixty-five per-cent of which are attributed to equipment. In the main, <em>detecting fire when no real fire is present</em>, e.g. cooking fumes, steam etc. Even though these fire detectors are doing what they are designed to do they obviously can’t differentiate between a real fire and a false alarm, but the disruption caused and cost to the community is enormous. To tackle this problem <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank"><strong>Rafiki Protection</strong></a> has developed the <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=twinflex+plus&amp;search_in_description=1" target="_blank"><strong>Twinflex plus system</strong></a> incorporating <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=checkpoint+alarm&amp;search_in_description=1" target="_blank">‘checkpoint’ alarm confirmation</a>.</p>
<h4>Extract from <a href="http://blog.sparksdirect.co.uk/tag/bs5839/">BS5839 Part 6</a> (Clause 12. Limitation of false alarms)</h4>
<blockquote><p>In some (usually larger) houses in multiple occupation, high levels of false alarms sometimes occur, simply as a result of the number different occupants, each of whom carry out activities, such as cooking, that can lead to false alarms. In such circumstances, occupiers have been known to compromise or even cause damage to, the fire detection and alarm system, or to ignore fire alarm signals. This makes it important to minimise, as far as practicable, the extent to which occupiers are disrupted by false alarms in other occupiers’ accommodation. This might, for example, be achieved by use of a mixed system (see 9.1.5)*. Alternatively, other measures might be adopted; for example, in the event of a fire signal in one dwelling unit, a short time delay might be incorporated for the occupier to investigate the cause and, if appropriate, reset the system before a fire alarm signal in other dwelling units.<br />
<em>* Mixed system <a href="http://blog.sparksdirect.co.uk/tag/bs5839/">BS5839 part 6 and BS5839 Part 1</a></em></p></blockquote>
<h4>Rafiki Checkpoint &#8211; Definition</h4>
<p>Alarm selection, the main feature of the <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=twinflex+plus&amp;search_in_description=1" target="_blank">Rafiki Twinflex plus </a>is the ability to set a pre-alarm in individual rooms or apartments but at the same time initiate full alarm should fire be detected in any communal area. This is made possible by <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">a detector sounder</a> ‘logical link’ feature. This is the first time that this feature has been made available on a conventional system and is beneficial where two stage alarms are required.</p>
<p><a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=twinflex+plus&amp;search_in_description=1"><img class="alignleft" title="Using the Twinflex Plus system in an installation - planning" src="http://blog.sparksdirect.co.uk/images/twinflex-planning.jpg" alt="" width="350" height="196" /></a>At the planning stage of installation fire zones are designated as <span style="text-decoration: underline;">‘dwelling’</span> or <span style="text-decoration: underline;">‘communal’</span>. Detectors in dwelling zones (e.g. apartments, hotel rooms etc.) are enabled with the ‘logical link’ feature by way of a dil switch in the detector. This then allows <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank">the control panel</a> to be, simply, programmed with a variable time alarm confirmation period (1-5 minutes at one minute increments). In the event of a fire being detected in a dwelling only the local (room) sounder will operate to alarm occupants of that particular dwelling.</p>
<p><a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank">The control panel</a> will then carry out a number of checks over this period (which may be 2 minutes, for example ) to confirm the detector is still in alarm and is a genuine fire, not a false alarm generated by cooking fumes, steam etc. If at the end of this checking period the detector ceases to signal alarm the control panel will automatically reset the detector/sounder and the system will revert to its normal state.</p>
<p><a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1"><img class="alignleft" title="Rafiki Twinflex - planning, if any problems come up" src="http://blog.sparksdirect.co.uk/images/twinflex-fire.jpg" alt="" width="350" height="198" /></a> If, however, at the end of the confirmation check the detector is still generating an alarm signal the control panel will instantly sound all alarms in the building for full evacuation. Detectors sensing fire, or, call point activation (in any zone) in communal areas instantly generate a full alarm throughout the building.</p>
<ul>
<li><a href="http://www.sparksdirect.co.uk/2-zone-twinflex-plus-fire-alarm-contractor-kit-from-rafiki-p-15340.html" target="_blank">The control panel</a> meets all the requirements of EN54-2 and EN54-4:1997.</li>
<li><a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a" target="_blank">The detector</a> meets the requirements of EN54-5 and EN54-7 :2000.</li>
<li><a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a" target="_blank">The sounder</a> meets the requirements of EN54-3:2001.</li>
</ul>
<blockquote><p><strong>NOTE:</strong> <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank"><strong>Twinflex Plus panels</strong></a> are configured to have ‘Dwelling’ or ‘Communal’ zones at the time of commissioning. Dwelling zones are then set with the ‘checking’ period &#8211; between 1 and 5 minutes. <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank"><strong>Rafiki</strong></a> advises that this panel should only be installed and configured by qualified fire alarm installers or equivalent personnel.</p></blockquote>
<h4>Using the Twinflex Plus system in an installation</h4>
<p>At the planning stage, fire zones are designated as either <span style="text-decoration: underline;">‘Dwelling’</span> or <span style="text-decoration: underline;">‘Communal’</span>. <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">Multipoint detectors</a> in the dwelling zones have the facility to use ‘checkpoint’ technology. By simply enabling the logical link dil switch in the detector. <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=checkpoint+alarm&amp;search_in_description=1" target="_blank">The ‘Checkpoint’ technology</a> is the ability to select a checking period for individual detectors to confirm the smoke/heat detected as a genuine fire not an false alarm. <em>This checking period</em> can be selected between 1 – 5 minutes at commissioning stage after consultation with fire officers or other authorized bodies.</p>
<p><strong><a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a"><img class="alignleft" title="Communal area, e.g. hall/stairway; kitchen; lounge." src="http://blog.sparksdirect.co.uk/images/twinflex-communal.jpg" alt="" width="210" height="154" /></a>Communal Zone</strong><br />
Communal area, e.g. hall/stairway; kitchen; lounge. When a detector alarm is activated on this type of zone, the control panel enters the fire state and the alarms are activated immediately in all zones throughout the installation.</p>
<p><strong><a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a"><img class="alignright" title="Single Dwelling per Zone (Zonal confirmation alarm)" src="http://blog.sparksdirect.co.uk/images/twinflex-single.jpg" alt="" width="210" height="130" /></a></strong><strong>Single Dwelling per Zone</strong> (Zonal confirmation alarm) e.g. flats with more than one room</p>
<p>When a detector alarm is activated on this type of zone, all sounders on the zone are activated and then the control panel carries out the configured number of confirmation checks.If the detector alarm is confirmed, the control panel enters the fire state and the alarms are activated throughout the installation; if the detector alarm is rejected, the sounders on the zone are silenced, and the detector in alarm is reset.</p>
<p><strong><a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=twinflex+plus&amp;search_in_description=1"><img class="alignleft" title="Multiple Dwellings per Zone (Local confirmation alarm)" src="http://blog.sparksdirect.co.uk/images/twinflex-multiple.jpg" alt="" width="210" height="92" /></a>Multiple Dwellings per Zone</strong> (Local confirmation alarm)<br />
Dwellings requiring a single detector/sounder, e.g. hostel; hall of residence; hotel rooms; bedsits.</p>
<p>When <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">a detector alarm</a> is detected on this type of zone, <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">the integral sounder in the detector</a> that generated the alarm signal is activated and then <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank">the control panel</a> carries out the configured number of confirmation checks. If the detector alarm is confirmed, the control panel enters the fire state and the alarms are activated throughout the installation; if the detector alarm is rejected, the sounder is silenced, and the detector reset.</p>
<p>Note: Activation of any manual call point will override alarm confirmation</p>
<p>Read more about the<a href="http://blog.sparksdirect.co.uk/user-responsibilities-in-the-testing-and-maintanance-of-the-fire-alarm-system/"> generally accepted guidelines</a> by <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank"><strong>Rafiki</strong></a>, <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=aico&amp;search_in_description=1" target="_blank"><strong>Aico</strong></a>, and other <a href="http://www.sparksdirect.co.uk/fire-and-security-fire-alarms-c-74_138.html" target="_blank"><strong>Fire Alarms</strong></a> manufacturers, (they are also commonly accepted for all the domestic, commercial and industrial properties in UK); the <span style="text-decoration: underline;">Rafiki advices for Fire Alarms</span>, some of the guidelines provided by <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank"><strong>Rafiki</strong></a>(intelligent fire technology) – check out <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank">the Rafiki series of industrial/commercial fire alarm systems</a> (like the <a href="../introducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint/">Rafiki Twinflex</a>), found at <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html" target="_blank">The Conventional</a> <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a" target="_blank">and Analogue</a> <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank">Fire Alarms</a>. For more details about <a href="http://www.fire-detect.co.uk/" target="_blank">the fire alarms</a>, visit the <a href="http://www.fire-detect.co.uk/" target="_blank"><strong>Fire-Detect</strong> website</a>(see a list of articles about the fire alarms <a href="http://www.sparksdirect.co.uk/page_4.html" target="_blank">here</a> and <a href="http://www.fire-detect.co.uk/questions-and-answers-aico-fire-detectors.html" target="_blank">here</a>).</p>

<div class="sociable">
<div class="sociable_tagline">
<strong>Share this article:</strong>
</div>
<ul>
	<li class="sociablefirst"><a rel="nofollow"  target="_blank" href="http://www.printfriendly.com/print?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;partner=sociable" title="Print"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/printfriendly.png" title="Print" alt="Print" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://digg.com/submit?phase=2&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;title=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms&amp;bodytext=With%20the%20Rafiki%20Twinflex%20Solutions%2C%20you%20have%20a%20%E2%80%98Checkpoint%E2%80%99%20alarm%20confirmation%20and%20HMO%E2%80%99s%20and%20you%20eliminate%20the%20problem%20of%20false%20alarms%20in%3A%20Hostels%2C%20Nursing%20Homes%2C%20Flats%2C%20Hotels%2C%20Bedsits%2C%20B%26amp%3BB%27s%2C%20etc.%0D%0A%0D%0A%20%20The%20Rafiki%20Twinflex%20plus%20is%20a%20patent" title="Digg"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/digg.png" title="Digg" alt="Digg" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://sphinn.com/index.php?c=post&amp;m=submit&amp;link=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F" title="Sphinn"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/sphinn.png" title="Sphinn" alt="Sphinn" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://delicious.com/post?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;title=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms&amp;notes=With%20the%20Rafiki%20Twinflex%20Solutions%2C%20you%20have%20a%20%E2%80%98Checkpoint%E2%80%99%20alarm%20confirmation%20and%20HMO%E2%80%99s%20and%20you%20eliminate%20the%20problem%20of%20false%20alarms%20in%3A%20Hostels%2C%20Nursing%20Homes%2C%20Flats%2C%20Hotels%2C%20Bedsits%2C%20B%26amp%3BB%27s%2C%20etc.%0D%0A%0D%0A%20%20The%20Rafiki%20Twinflex%20plus%20is%20a%20patent" title="del.icio.us"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/delicious.png" title="del.icio.us" alt="del.icio.us" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.facebook.com/share.php?u=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;t=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms" title="Facebook"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/facebook.png" title="Facebook" alt="Facebook" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.google.com/bookmarks/mark?op=edit&amp;bkmk=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;title=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms&amp;annotation=With%20the%20Rafiki%20Twinflex%20Solutions%2C%20you%20have%20a%20%E2%80%98Checkpoint%E2%80%99%20alarm%20confirmation%20and%20HMO%E2%80%99s%20and%20you%20eliminate%20the%20problem%20of%20false%20alarms%20in%3A%20Hostels%2C%20Nursing%20Homes%2C%20Flats%2C%20Hotels%2C%20Bedsits%2C%20B%26amp%3BB%27s%2C%20etc.%0D%0A%0D%0A%20%20The%20Rafiki%20Twinflex%20plus%20is%20a%20patent" title="Google Bookmarks"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/googlebookmark.png" title="Google Bookmarks" alt="Google Bookmarks" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="mailto:?subject=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms&amp;body=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F" title="email"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/email_link.png" title="email" alt="email" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.friendfeed.com/share?title=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms&amp;link=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F" title="FriendFeed"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/friendfeed.png" title="FriendFeed" alt="FriendFeed" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://hellotxt.com/?status=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms+http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F" title="HelloTxt"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/hellotxt.png" title="HelloTxt" alt="HelloTxt" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.linkedin.com/shareArticle?mini=true&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;title=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms&amp;source=Blog+Sparks+Direct+Reviews+of+the+lights%2C+dimmers%2C+switches+and+sockets%2C+electrical+items%2C+heating+and+ventilation%2C+fire+and+security+items+on+our+site&amp;summary=With%20the%20Rafiki%20Twinflex%20Solutions%2C%20you%20have%20a%20%E2%80%98Checkpoint%E2%80%99%20alarm%20confirmation%20and%20HMO%E2%80%99s%20and%20you%20eliminate%20the%20problem%20of%20false%20alarms%20in%3A%20Hostels%2C%20Nursing%20Homes%2C%20Flats%2C%20Hotels%2C%20Bedsits%2C%20B%26amp%3BB%27s%2C%20etc.%0D%0A%0D%0A%20%20The%20Rafiki%20Twinflex%20plus%20is%20a%20patent" title="LinkedIn"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/linkedin.png" title="LinkedIn" alt="LinkedIn" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="https://favorites.live.com/quickadd.aspx?marklet=1&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;title=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms" title="Live"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/live.png" title="Live" alt="Live" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.printfriendly.com/print?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;partner=sociable" title="PDF"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/pdf.png" title="PDF" alt="PDF" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://posterous.com/share?linkto=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;title=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms&amp;selection=With%20the%20Rafiki%20Twinflex%20Solutions%2C%20you%20have%20a%20%E2%80%98Checkpoint%E2%80%99%20alarm%20confirmation%20and%20HMO%E2%80%99s%20and%20you%20eliminate%20the%20problem%20of%20false%20alarms%20in%3A%20Hostels%2C%20Nursing%20Homes%2C%20Flats%2C%20Hotels%2C%20Bedsits%2C%20B%26amp%3BB%27s%2C%20etc.%0D%0A%0D%0A%20%20The%20Rafiki%20Twinflex%20plus%20is%20a%20patent" title="Posterous"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/posterous.png" title="Posterous" alt="Posterous" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://reddit.com/submit?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;title=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms" title="Reddit"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/reddit.png" title="Reddit" alt="Reddit" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.stumbleupon.com/submit?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;title=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms" title="StumbleUpon"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/stumbleupon.png" title="StumbleUpon" alt="StumbleUpon" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://buzz.yahoo.com/submit/?submitUrl=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F&amp;submitHeadline=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms&amp;submitSummary=With%20the%20Rafiki%20Twinflex%20Solutions%2C%20you%20have%20a%20%E2%80%98Checkpoint%E2%80%99%20alarm%20confirmation%20and%20HMO%E2%80%99s%20and%20you%20eliminate%20the%20problem%20of%20false%20alarms%20in%3A%20Hostels%2C%20Nursing%20Homes%2C%20Flats%2C%20Hotels%2C%20Bedsits%2C%20B%26amp%3BB%27s%2C%20etc.%0D%0A%0D%0A%20%20The%20Rafiki%20Twinflex%20plus%20is%20a%20patent&amp;submitCategory=science&amp;submitAssetType=text" title="Yahoo! Buzz"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/yahoobuzz.png" title="Yahoo! Buzz" alt="Yahoo! Buzz" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://technorati.com/faves?add=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F" title="Technorati"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/technorati.png" title="Technorati" alt="Technorati" class="sociable-hovers" /></a></li>
	<li class="sociablelast"><a rel="nofollow"  target="_blank" href="http://twitter.com/home?status=Checkpoint%20alarm%20confirmation%20and%20HMO%E2%80%99s%3A%20Eliminate%20the%20problem%20of%20false%20alarms%20-%20http%3A%2F%2Fblog.sparksdirect.co.uk%2Fcheckpoint-alarm-confirmation-and-hmo%25e2%2580%2599s-eliminate-the-problem-of-false-alarms%2F" title="Twitter"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/twitter.png" title="Twitter" alt="Twitter" class="sociable-hovers" /></a></li>
</ul>
</div>
]]></content:encoded>
			<wfw:commentRss>http://blog.sparksdirect.co.uk/checkpoint-alarm-confirmation-and-hmo%e2%80%99s-eliminate-the-problem-of-false-alarms/feed/</wfw:commentRss>
		<slash:comments>1</slash:comments>
		</item>
		<item>
		<title>Fire Detection &amp; Alarm Systems BS5839, fire risk assessment &amp; system zoning, Rafiki</title>
		<link>http://blog.sparksdirect.co.uk/fire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki/</link>
		<comments>http://blog.sparksdirect.co.uk/fire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki/#comments</comments>
		<pubDate>Thu, 11 Jun 2009 08:13:04 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[ask Mr Sparks]]></category>
		<category><![CDATA[customer service]]></category>
		<category><![CDATA[fire alarms]]></category>
		<category><![CDATA[standards and regulations]]></category>
		<category><![CDATA[technical data]]></category>
		<category><![CDATA[bs5839]]></category>
		<category><![CDATA[emergency plan]]></category>
		<category><![CDATA[fire alarm systems]]></category>
		<category><![CDATA[fire detectors]]></category>
		<category><![CDATA[fire precautions]]></category>
		<category><![CDATA[fire risk assessment]]></category>
		<category><![CDATA[Rafiki]]></category>
		<category><![CDATA[rafiki twinflex]]></category>
		<category><![CDATA[remote indicator lamps]]></category>
		<category><![CDATA[risk of fire]]></category>

		<guid isPermaLink="false">http://blog.sparksdirect.co.uk/?p=1309</guid>
		<description><![CDATA[
A fire risk assessment should identify:

Possible hazards;
Sources of ignition;
Persons at risk of fire;
Means of escape;
Fire detection and alarm systems;
Fire fighting facilities;
Routing procedure in the event of fire;
Any difficulties with the above &#8211; and plans to put them right.


Fire Detection &#38; Alarm Systems BS5839 &#8211; Risk Assessment

The &#8216;Fire precautions (Workplace) Regulations&#8217; require any business employing five [...]]]></description>
			<content:encoded><![CDATA[<p><a name="fire"></a></p>
<h4>A fire risk assessment should identify:</h4>
<ul>
<li>Possible hazards;</li>
<li>Sources of ignition;</li>
<li>Persons at risk of fire;</li>
<li>Means of escape;</li>
<li>Fire detection and alarm systems;</li>
<li>Fire fighting facilities;</li>
<li>Routing procedure in the event of fire;</li>
<li>Any difficulties with the above &#8211; and plans to put them right.</li>
</ul>
<p><a name="bs5839"></a></p>
<h4>Fire Detection &amp; Alarm Systems BS5839 &#8211; Risk Assessment</h4>
<ul>
<li>The <a href="http://www.google.co.uk/search?hl=en&amp;num=50&amp;q=%27Fire+precautions+(Workplace)+Regulations%27&amp;btnG=Search&amp;meta=" target="_blank">&#8216;Fire precautions (Workplace) Regulations&#8217;</a> require any business employing five or more persons to hold a written &#8216;<span style="text-decoration: underline;">Fire Risk Assessment&#8217;</span> and <span style="text-decoration: underline;">&#8216;Emergency Plan&#8217;</span>.  This must be periodically reviewed.</li>
<li>The local fire brigade can enforce compliance, and close any building that does not meet this act.</li>
<li>In the event of a fire in a building without a written <span style="text-decoration: underline;">&#8216;Fire Risk Assessment&#8217;</span>, those responsible may face fines and imprisonment, and/or private litigation.</li>
</ul>
<h4>The Law requires you to</h4>
<ul>
<li><em>Complete a fire risk assessment for your work place</em> (considering all employees, the public, disabled people and people with special needs).</li>
<li>Identify and record any <em>significant findings or persons at risk</em>.</li>
<li>Provide and maintain <em>fire precautions</em>.</li>
<li>Provide information, instruction and training.</li>
<li>Nominat e <em>persons responsible</em> to implement your emergency plan.</li>
<li><em>Consult employees</em> about the above nominations and your proposals to improve fire precautions.</li>
<li><em>Inform other employees</em> who may have work places in the building about any significant risks which may affect their safety and co-operate with them to reduce/control these risks.</li>
<li>If you are not an employer, but control premises which contain more than one workplace, <em>you are responsible for complying with fire regulations</em>.</li>
<li>You must <em>establish a suitable means of contacting the emergency services</em>.</li>
<li>Your employees must co-operate to <em>ensure the workplace is safe from fire and its effects</em>.</li>
</ul>
<p><a name="zoning"></a></p>
<h4>Fire Risk Assessment &#8211; System Zoning Information</h4>
<p>In order to aid identification of the source of a possible fire, the protected building should be divided into <span style="text-decoration: underline;">&#8216;zones&#8217;</span>.  When deciding on a suitable zoning scheme for a building, consideration should be given to <em>the size, any existing fire routines, escape routes, zone accessibility, and structural fire compartmentation</em>.</p>
<p><em><strong>The following guide lines should be observed:</strong></em></p>
<ul>
<li>If the total floor area of the building is <strong>less than 300sqm </strong>then the building needs only one zone, regardless of the number of storeys.<br />
<strong>If the total floor area is greater than 300 sqm:</strong></li>
<li>The maximum area for a zone is 2000sqm.</li>
<li>If a stairwell (or similar) extends beyond one floor it should be <em>a separate zone</em>.</li>
<li>If a zone covers  more than one fire compartment then the zone boundaries should follow the compartment boundaries.</li>
<li>The search distance within the zone in order to ascertain the position of the fire should not exceed 60m.  Remember that the use of <em>Remote Indicator lamps</em> may help to reduce the distance traveled.</li>
<li>If a building is divided between occupiers, zones must not be shared between them.</li>
</ul>
<h4><a href="http://www.sparksdirect.co.uk/rafiki-twinflex-hatari-sounder-red-sounder-p-15333.html" target="_blank"><img class="alignleft" title="Rafiki Twinflex Hatari Sounder, Red sounder" src="http://www.sparksdirect.co.uk/images/lights/3020001.thb100.jpg" alt="Rafiki Twinflex Hatari Sounder, Red sounder" width="100" height="75" /></a></h4>
<p>These are some of the guidelines provided by <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank"><strong>Rafiki</strong></a>(intelligent fire technology) &#8211; check out <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank">the Rafiki series of industrial/commercial fire alarm systems</a> (like the <a href="http://blog.sparksdirect.co.uk/introducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint/">Rafiki Twinflex</a>), found at <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html" target="_blank">The Conventional</a> <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a" target="_blank">and Analogue</a> <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank">Fire Alarms</a>. For more details about <a href="http://www.fire-detect.co.uk/" target="_blank">the fire alarms</a>, visit the <a href="http://www.fire-detect.co.uk/" target="_blank"><strong>Fire-Detect</strong> website</a>(see a list of articles about the fire alarms <a href="http://www.sparksdirect.co.uk/page_4.html" target="_blank">here</a> and <a href="http://www.fire-detect.co.uk/questions-and-answers-aico-fire-detectors.html" target="_blank">here</a>).</p>

<div class="sociable">
<div class="sociable_tagline">
<strong>Share this article:</strong>
</div>
<ul>
	<li class="sociablefirst"><a rel="nofollow"  target="_blank" href="http://www.printfriendly.com/print?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;partner=sociable" title="Print"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/printfriendly.png" title="Print" alt="Print" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://digg.com/submit?phase=2&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;title=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki&amp;bodytext=%0D%0AA%20fire%20risk%20assessment%20should%20identify%3A%0D%0A%0D%0A%09Possible%20hazards%3B%0D%0A%09Sources%20of%20ignition%3B%0D%0A%09Persons%20at%20risk%20of%20fire%3B%0D%0A%09Means%20of%20escape%3B%0D%0A%09Fire%20detection%20and%20alarm%20systems%3B%0D%0A%09Fire%20fighting%20facilities%3B%0D%0A%09Routing%20procedure%20in%20the%20event%20of%20fire%3B%0D%0A%09Any%20diffi" title="Digg"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/digg.png" title="Digg" alt="Digg" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://sphinn.com/index.php?c=post&amp;m=submit&amp;link=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F" title="Sphinn"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/sphinn.png" title="Sphinn" alt="Sphinn" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://delicious.com/post?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;title=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki&amp;notes=%0D%0AA%20fire%20risk%20assessment%20should%20identify%3A%0D%0A%0D%0A%09Possible%20hazards%3B%0D%0A%09Sources%20of%20ignition%3B%0D%0A%09Persons%20at%20risk%20of%20fire%3B%0D%0A%09Means%20of%20escape%3B%0D%0A%09Fire%20detection%20and%20alarm%20systems%3B%0D%0A%09Fire%20fighting%20facilities%3B%0D%0A%09Routing%20procedure%20in%20the%20event%20of%20fire%3B%0D%0A%09Any%20diffi" title="del.icio.us"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/delicious.png" title="del.icio.us" alt="del.icio.us" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.facebook.com/share.php?u=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;t=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki" title="Facebook"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/facebook.png" title="Facebook" alt="Facebook" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.google.com/bookmarks/mark?op=edit&amp;bkmk=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;title=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki&amp;annotation=%0D%0AA%20fire%20risk%20assessment%20should%20identify%3A%0D%0A%0D%0A%09Possible%20hazards%3B%0D%0A%09Sources%20of%20ignition%3B%0D%0A%09Persons%20at%20risk%20of%20fire%3B%0D%0A%09Means%20of%20escape%3B%0D%0A%09Fire%20detection%20and%20alarm%20systems%3B%0D%0A%09Fire%20fighting%20facilities%3B%0D%0A%09Routing%20procedure%20in%20the%20event%20of%20fire%3B%0D%0A%09Any%20diffi" title="Google Bookmarks"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/googlebookmark.png" title="Google Bookmarks" alt="Google Bookmarks" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="mailto:?subject=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki&amp;body=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F" title="email"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/email_link.png" title="email" alt="email" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.friendfeed.com/share?title=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki&amp;link=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F" title="FriendFeed"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/friendfeed.png" title="FriendFeed" alt="FriendFeed" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://hellotxt.com/?status=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki+http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F" title="HelloTxt"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/hellotxt.png" title="HelloTxt" alt="HelloTxt" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.linkedin.com/shareArticle?mini=true&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;title=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki&amp;source=Blog+Sparks+Direct+Reviews+of+the+lights%2C+dimmers%2C+switches+and+sockets%2C+electrical+items%2C+heating+and+ventilation%2C+fire+and+security+items+on+our+site&amp;summary=%0D%0AA%20fire%20risk%20assessment%20should%20identify%3A%0D%0A%0D%0A%09Possible%20hazards%3B%0D%0A%09Sources%20of%20ignition%3B%0D%0A%09Persons%20at%20risk%20of%20fire%3B%0D%0A%09Means%20of%20escape%3B%0D%0A%09Fire%20detection%20and%20alarm%20systems%3B%0D%0A%09Fire%20fighting%20facilities%3B%0D%0A%09Routing%20procedure%20in%20the%20event%20of%20fire%3B%0D%0A%09Any%20diffi" title="LinkedIn"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/linkedin.png" title="LinkedIn" alt="LinkedIn" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="https://favorites.live.com/quickadd.aspx?marklet=1&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;title=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki" title="Live"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/live.png" title="Live" alt="Live" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.printfriendly.com/print?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;partner=sociable" title="PDF"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/pdf.png" title="PDF" alt="PDF" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://posterous.com/share?linkto=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;title=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki&amp;selection=%0D%0AA%20fire%20risk%20assessment%20should%20identify%3A%0D%0A%0D%0A%09Possible%20hazards%3B%0D%0A%09Sources%20of%20ignition%3B%0D%0A%09Persons%20at%20risk%20of%20fire%3B%0D%0A%09Means%20of%20escape%3B%0D%0A%09Fire%20detection%20and%20alarm%20systems%3B%0D%0A%09Fire%20fighting%20facilities%3B%0D%0A%09Routing%20procedure%20in%20the%20event%20of%20fire%3B%0D%0A%09Any%20diffi" title="Posterous"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/posterous.png" title="Posterous" alt="Posterous" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://reddit.com/submit?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;title=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki" title="Reddit"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/reddit.png" title="Reddit" alt="Reddit" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.stumbleupon.com/submit?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;title=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki" title="StumbleUpon"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/stumbleupon.png" title="StumbleUpon" alt="StumbleUpon" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://buzz.yahoo.com/submit/?submitUrl=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F&amp;submitHeadline=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki&amp;submitSummary=%0D%0AA%20fire%20risk%20assessment%20should%20identify%3A%0D%0A%0D%0A%09Possible%20hazards%3B%0D%0A%09Sources%20of%20ignition%3B%0D%0A%09Persons%20at%20risk%20of%20fire%3B%0D%0A%09Means%20of%20escape%3B%0D%0A%09Fire%20detection%20and%20alarm%20systems%3B%0D%0A%09Fire%20fighting%20facilities%3B%0D%0A%09Routing%20procedure%20in%20the%20event%20of%20fire%3B%0D%0A%09Any%20diffi&amp;submitCategory=science&amp;submitAssetType=text" title="Yahoo! Buzz"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/yahoobuzz.png" title="Yahoo! Buzz" alt="Yahoo! Buzz" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://technorati.com/faves?add=http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F" title="Technorati"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/technorati.png" title="Technorati" alt="Technorati" class="sociable-hovers" /></a></li>
	<li class="sociablelast"><a rel="nofollow"  target="_blank" href="http://twitter.com/home?status=Fire%20Detection%20%26%20Alarm%20Systems%20BS5839%2C%20fire%20risk%20assessment%20%26%20system%20zoning%2C%20Rafiki%20-%20http%3A%2F%2Fblog.sparksdirect.co.uk%2Ffire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki%2F" title="Twitter"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/twitter.png" title="Twitter" alt="Twitter" class="sociable-hovers" /></a></li>
</ul>
</div>
]]></content:encoded>
			<wfw:commentRss>http://blog.sparksdirect.co.uk/fire-detection-alarm-systems-bs5839-fire-risk-assessment-system-zoning-rafiki/feed/</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
		<item>
		<title>Introducing Rafiki Twinflex, conventional fire alarm systems, multipoint</title>
		<link>http://blog.sparksdirect.co.uk/introducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint/</link>
		<comments>http://blog.sparksdirect.co.uk/introducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint/#comments</comments>
		<pubDate>Tue, 09 Jun 2009 15:48:25 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[fire alarms]]></category>
		<category><![CDATA[new technologies]]></category>
		<category><![CDATA[technical data]]></category>
		<category><![CDATA[website update]]></category>
		<category><![CDATA[2-wire fire alarm system]]></category>
		<category><![CDATA[fire alarm control panel]]></category>
		<category><![CDATA[manual call point]]></category>
		<category><![CDATA[multipoint detector]]></category>
		<category><![CDATA[Rafiki]]></category>
		<category><![CDATA[rafiki twinflex]]></category>
		<category><![CDATA[smoke and heat alarm]]></category>
		<category><![CDATA[smoke and heat detector]]></category>
		<category><![CDATA[sounder]]></category>
		<category><![CDATA[twinflex multipoint]]></category>

		<guid isPermaLink="false">http://blog.sparksdirect.co.uk/?p=1303</guid>
		<description><![CDATA[In this article we would like to introduce Rafiki TwinFlex: The Twinflex conventional fire alarm system incorporating the Multipoint combined smoke and heat detector with built in sounder means the whole system can be installed using only one pair of wires.
The Multipoint Detector &#8211; Twinflex
Using the Multipoint detector as part of the Twinflex 2-wire fire [...]]]></description>
			<content:encoded><![CDATA[<p><a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=multipoint&amp;search_in_description=1"><img class="alignleft" title="Multipoint Twinflex from Rafiki - the diagram" src="http://blog.sparksdirect.co.uk/images/twinflex-diagram.jpg" alt="" width="377" height="241" /></a>In this article we would like to introduce <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=rafiki&amp;search_in_description=1" target="_blank"><strong>Rafiki</strong></a> <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=twinflex&amp;search_in_description=1" target="_blank">TwinFlex</a>: <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a" target="_blank">The Twinflex conventional fire alarm system</a> incorporating <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">the Multipoint combined smoke and heat detector with built in sounder</a> means the whole system can be installed using only one pair of wires.</p>
<h4>The Multipoint Detector &#8211; Twinflex</h4>
<p>Using the <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a" target="_blank"><strong>Multipoint detector</strong></a> as part of <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank"><strong>the Twinflex 2-wire fire alarm system</strong></a> means that <em>when a detector is wired in, a sounder is wired in too</em> – with no extra wiring, therefore greatly reducing the number of points that need to be installed and the time it takes to install them.</p>
<p style="text-align: right;"><a href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-detector-with-no-sounder-p-15332.html"><img class="alignright" title="Rafiki Twinflex Multipoint Detector with No Sounder" src="http://blog.sparksdirect.co.uk/images/multipoint-twinflex-1.jpg" alt="" width="165" height="151" /></a>As <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=multipoint&amp;search_in_description=1" target="_blank">the Multipoint</a> offers 7 different modes of detection, the installation is made even simpler as this one device suits all applications. Whatever type of detection is required, for any part of the installation it can be selected by the flick of a switch at the time of commissioning. Any one of 3 different smoke modes, 2 fixed temperature heat modes, a rate of rise mode and a combination smoke or heat mode can be selected.</p>
<p>As <a href="http://www.sparksdirect.co.uk/advanced_search_result.html?y=0&amp;x=0&amp;keyword=Twinflex+Multipoint+detect&amp;search_in_description=1" target="_blank"><strong>the Twinflex Multipoint detector</strong></a> is available with or without a full specification 90 dB(A) sounder (for only a marginal cost difference) no extra devices need to be purchased when audible warning is required. (Meets audibility levels recommended in <a href="http://www.bsigroup.com/en/Shop/Publication-Detail/?pid=000000000000862786" target="_blank">BS5839 Part 1:1988</a>). <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-manual-call-point-with-sounder-p-15336.html" target="_blank">Twinflex Manual Call Points</a> can be run on the same pair of wires as detectors. Both detectors and <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-manual-call-point-p-15335.html" target="_blank">Manual Call Points</a> have <em>a built in EOL switch</em> so that any device may be set as the end of line monitor. The panel can also differentiate between a Manual Call Point and a Detector alarm.</p>
<p><a href="http://www.sparksdirect.co.uk/rafiki-twinflex-hatari-sounder-white-sounder-p-15334.html"><img class="alignleft" title="Rafiki Twinflex Hatari Sounder, Red or White sounder" src="http://blog.sparksdirect.co.uk/images/multipoint-twinflex-2.jpg" alt="" width="160" height="157" /></a>If extra sound is required, or for areas that do not require detection, then <a href="http://www.sparksdirect.co.uk/rafiki-twinflex-hatari-sounder-red-sounder-p-15333.html" target="_blank"><strong>the Twinflex Hatari sounder</strong></a> may be used on the same two wires, offering sound output of 100dB(A). It also has a built in EOL monitoring switch.</p>
<p><a href="http://www.sparksdirect.co.uk/2-zone-twinflex-plus-fire-alarm-control-panel-p-15337.html" target="_blank"><strong>The panel</strong></a> can accommodate up to 32 devices per zone, has separate fault monitoring displays for each zone, and a one man walk test facility. Zones are configured without the need to use resistors or capacitors on unused zones.</p>
<h4>The Rafiki TwinFlex &#8211; features</h4>
<ul>
<li><span style="text-decoration: underline;">Two wire installation</span> – only one circuit per zone to connect detectors and sounders – installation savings can be as high as 40%</li>
<li><span style="text-decoration: underline;">Break glass identification.</span> The panel has the ability to differentiate between call point or detector alarms.</li>
<li><span style="text-decoration: underline;">Built in end of line device.</span> All devices, including detectors, manual call points and sounders have a built in end of line monitoring function. Simply flicking a switch within any device will enable end of line monitoring. No resistors or extra circuits are required.</li>
<li><span style="text-decoration: underline;">No base diode requirement.</span></li>
<li><span style="text-decoration: underline;">Seven modes of detection.</span></li>
<li>System <span style="text-decoration: underline;">fully complies</span> to BS and EN.</li>
<li><span style="text-decoration: underline;">32 devices</span> per zone.</li>
<li><span style="text-decoration: underline;">Easy to install</span> – no need to worry about marking “in’s” and “out’s”.</li>
<li>Available in <span style="text-decoration: underline;">2, 4 &amp; 8 zone panels</span>.</li>
<li>72 hour <span style="text-decoration: underline;">standby</span>.</li>
<li>All panels have <span style="text-decoration: underline;">1 auxiliary sounder circuit</span> (500mA).</li>
<li>8 and 16 zone repeater panels available.</li>
<li><span style="text-decoration: underline;">Input &amp; Output modules</span> available for plant shutdown, door release, etc.</li>
<li><span style="text-decoration: underline;">Savings</span> in cable costs.</li>
<li><span style="text-decoration: underline;">Savings</span> in installation costs.</li>
<li>Multipoint Detector/Sounder <span style="text-decoration: underline;">saves the cost</span> of a sounder.</li>
</ul>
<h4>Rafiki Twinflex &#8211; Technical specifications</h4>
<ul>
<li> <strong>Battery:</strong> 2/4 zone – 2 x 12v 2.1Ah, 8 zone – 2 x 12v 3.3Ah</li>
<li><strong>Panel Dimensions (WxHxD):</strong> 2/4 zone – 310 x 243 x 85 mm, 8 zone – 315 x 400 x 90 mm</li>
<li><strong>Panel Construction:</strong> 2/4 zone – fire retardant plastic, 8 zone – mild steel</li>
<li><strong>Mains Voltage: </strong>230 volts AC +10% -15% 50Hz</li>
<li><strong>Operating Voltage:</strong> 24 volts DC</li>
</ul>
<p>Buy online <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a" target="_blank">the Rafiki series of conventional fire alarms:</a></p>
<ul>
<li><a title="Rafiki Twinflex Hatari Sounder, White sounder" href="http://www.sparksdirect.co.uk/rafiki-twinflex-hatari-sounder-white-sounder-p-15334.html" target="_blank">Rafiki Twinflex Hatari Sounder, White sounder</a>;</li>
<li><a title="Rafiki Twinflex Multipoint Combined Detector and Sounder" href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-combined-detector-and-sounder-p-15331.html" target="_blank">Rafiki Twinflex Multipoint Combined Detector and Sounder</a>;</li>
<li><a title="Rafiki Twinflex Multipoint Detector with No Sounder" href="http://www.sparksdirect.co.uk/rafiki-twinflex-multipoint-detector-with-no-sounder-p-15332.html" target="_blank"></a><a title="Rafiki Twinflex Manual Call Point with Sounder" href="http://www.sparksdirect.co.uk/rafiki-twinflex-manual-call-point-with-sounder-p-15336.html" target="_blank">Rafiki Twinflex Manual Call Point with Sounder</a>;</li>
<li><a title="2 Zone Twinflex PLUS Fire Alarm Control Panel" href="http://www.sparksdirect.co.uk/2-zone-twinflex-plus-fire-alarm-control-panel-p-15337.html" target="_blank">2 Zone Twinflex PLUS Fire Alarm Control Panel</a>;</li>
<li><a title="8 Zone Twinflex PLUS Fire Alarm Control Panel Rafiki" href="http://www.sparksdirect.co.uk/8-zone-twinflex-plus-fire-alarm-control-panel-rafiki-p-15339.html" target="_blank">8 Zone Twinflex PLUS Fire Alarm Control Panel Rafiki</a>;</li>
</ul>
<p>at the Fire Alarms, <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=2&amp;sort=20a" target="_blank">Conventional and Analogue</a> <a href="http://www.sparksdirect.co.uk/fire-alarms-conventional-analogue-systems-c-74_138_144.html?page=3&amp;sort=20a" target="_blank">Fire Alarms section</a>.</p>

<div class="sociable">
<div class="sociable_tagline">
<strong>Share this article:</strong>
</div>
<ul>
	<li class="sociablefirst"><a rel="nofollow"  target="_blank" href="http://www.printfriendly.com/print?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;partner=sociable" title="Print"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/printfriendly.png" title="Print" alt="Print" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://digg.com/submit?phase=2&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;title=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint&amp;bodytext=In%20this%20article%20we%20would%20like%20to%20introduce%20Rafiki%20TwinFlex%3A%20The%20Twinflex%20conventional%20fire%20alarm%20system%20incorporating%20the%20Multipoint%20combined%20smoke%20and%20heat%20detector%20with%20built%20in%20sounder%20means%20the%20whole%20system%20can%20be%20installed%20using%20only%20one%20pair%20of" title="Digg"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/digg.png" title="Digg" alt="Digg" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://sphinn.com/index.php?c=post&amp;m=submit&amp;link=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F" title="Sphinn"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/sphinn.png" title="Sphinn" alt="Sphinn" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://delicious.com/post?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;title=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint&amp;notes=In%20this%20article%20we%20would%20like%20to%20introduce%20Rafiki%20TwinFlex%3A%20The%20Twinflex%20conventional%20fire%20alarm%20system%20incorporating%20the%20Multipoint%20combined%20smoke%20and%20heat%20detector%20with%20built%20in%20sounder%20means%20the%20whole%20system%20can%20be%20installed%20using%20only%20one%20pair%20of" title="del.icio.us"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/delicious.png" title="del.icio.us" alt="del.icio.us" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.facebook.com/share.php?u=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;t=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint" title="Facebook"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/facebook.png" title="Facebook" alt="Facebook" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.google.com/bookmarks/mark?op=edit&amp;bkmk=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;title=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint&amp;annotation=In%20this%20article%20we%20would%20like%20to%20introduce%20Rafiki%20TwinFlex%3A%20The%20Twinflex%20conventional%20fire%20alarm%20system%20incorporating%20the%20Multipoint%20combined%20smoke%20and%20heat%20detector%20with%20built%20in%20sounder%20means%20the%20whole%20system%20can%20be%20installed%20using%20only%20one%20pair%20of" title="Google Bookmarks"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/googlebookmark.png" title="Google Bookmarks" alt="Google Bookmarks" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="mailto:?subject=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint&amp;body=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F" title="email"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/email_link.png" title="email" alt="email" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.friendfeed.com/share?title=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint&amp;link=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F" title="FriendFeed"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/friendfeed.png" title="FriendFeed" alt="FriendFeed" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://hellotxt.com/?status=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint+http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F" title="HelloTxt"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/hellotxt.png" title="HelloTxt" alt="HelloTxt" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.linkedin.com/shareArticle?mini=true&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;title=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint&amp;source=Blog+Sparks+Direct+Reviews+of+the+lights%2C+dimmers%2C+switches+and+sockets%2C+electrical+items%2C+heating+and+ventilation%2C+fire+and+security+items+on+our+site&amp;summary=In%20this%20article%20we%20would%20like%20to%20introduce%20Rafiki%20TwinFlex%3A%20The%20Twinflex%20conventional%20fire%20alarm%20system%20incorporating%20the%20Multipoint%20combined%20smoke%20and%20heat%20detector%20with%20built%20in%20sounder%20means%20the%20whole%20system%20can%20be%20installed%20using%20only%20one%20pair%20of" title="LinkedIn"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/linkedin.png" title="LinkedIn" alt="LinkedIn" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="https://favorites.live.com/quickadd.aspx?marklet=1&amp;url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;title=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint" title="Live"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/live.png" title="Live" alt="Live" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.printfriendly.com/print?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;partner=sociable" title="PDF"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/pdf.png" title="PDF" alt="PDF" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://posterous.com/share?linkto=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;title=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint&amp;selection=In%20this%20article%20we%20would%20like%20to%20introduce%20Rafiki%20TwinFlex%3A%20The%20Twinflex%20conventional%20fire%20alarm%20system%20incorporating%20the%20Multipoint%20combined%20smoke%20and%20heat%20detector%20with%20built%20in%20sounder%20means%20the%20whole%20system%20can%20be%20installed%20using%20only%20one%20pair%20of" title="Posterous"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/posterous.png" title="Posterous" alt="Posterous" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://reddit.com/submit?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;title=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint" title="Reddit"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/reddit.png" title="Reddit" alt="Reddit" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://www.stumbleupon.com/submit?url=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;title=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint" title="StumbleUpon"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/stumbleupon.png" title="StumbleUpon" alt="StumbleUpon" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://buzz.yahoo.com/submit/?submitUrl=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F&amp;submitHeadline=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint&amp;submitSummary=In%20this%20article%20we%20would%20like%20to%20introduce%20Rafiki%20TwinFlex%3A%20The%20Twinflex%20conventional%20fire%20alarm%20system%20incorporating%20the%20Multipoint%20combined%20smoke%20and%20heat%20detector%20with%20built%20in%20sounder%20means%20the%20whole%20system%20can%20be%20installed%20using%20only%20one%20pair%20of&amp;submitCategory=science&amp;submitAssetType=text" title="Yahoo! Buzz"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/yahoobuzz.png" title="Yahoo! Buzz" alt="Yahoo! Buzz" class="sociable-hovers" /></a></li>
	<li><a rel="nofollow"  target="_blank" href="http://technorati.com/faves?add=http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F" title="Technorati"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/technorati.png" title="Technorati" alt="Technorati" class="sociable-hovers" /></a></li>
	<li class="sociablelast"><a rel="nofollow"  target="_blank" href="http://twitter.com/home?status=Introducing%20Rafiki%20Twinflex%2C%20conventional%20fire%20alarm%20systems%2C%20multipoint%20-%20http%3A%2F%2Fblog.sparksdirect.co.uk%2Fintroducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint%2F" title="Twitter"><img src="http://blog.sparksdirect.co.uk/wp-content/plugins/sociable/images/twitter.png" title="Twitter" alt="Twitter" class="sociable-hovers" /></a></li>
</ul>
</div>
]]></content:encoded>
			<wfw:commentRss>http://blog.sparksdirect.co.uk/introducing-rafiki-twinflex-conventional-fire-alarm-systems-multipoint/feed/</wfw:commentRss>
		<slash:comments>3</slash:comments>
		</item>
	</channel>
</rss>